Test Code LABPBTCR TCRV Beta by Flow Cytometry, Blood
Synonym
- TKIT
- TCRVB
- TCR
- PBTCR
Profile Information
Reporting Name | Available Separately | Always Reported |
---|---|---|
CD13/14 | No | Yes |
CD19 | No | Yes |
CD2 | No | Yes |
CD26 | No | Yes |
CD3 | No | Yes |
CD4 | No | Yes |
CD56/16 | No | Yes |
CD7 | No | Yes |
CD8 | No | Yes |
Vb1 | No | Yes |
Vb11 | No | Yes |
Vb12 | No | Yes |
Vb13.1 | No | Yes |
Vb13.2 | No | Yes |
Vb13.6 | No | Yes |
Vb14 | No | Yes |
Vb16 | No | Yes |
Vb17 | No | Yes |
Vb18 | No | Yes |
Vb2 | No | Yes |
Vb20 | No | Yes |
Vb21.3 | No | Yes |
Vb22 | No | Yes |
Vb23 | No | Yes |
Vb3 | No | Yes |
Vb4 | No | Yes |
Vb5.1 | No | Yes |
Vb5.2 | No | Yes |
Vb5.3 | No | Yes |
Vb7.1 | No | Yes |
Vb7.2 | No | Yes |
Vb8 | No | Yes |
Vb9 | No | Yes |
Specimen Required
Specimen Type: Peripheral blood
Container/Tube:
Preferred: Lavender Top
Acceptable: Lavender Top, Sodium Heparin
Specimen Volume: 5-10 mL
Specimen Minimum Volume: 1 mL
Specimen Stability Information
Ambient: 24 hours
Rejected Due To
- Frozen specimens
- Clotted specimens
- Hemolysis
- Unlabeled specimens
- Improperly labeled specimens
Reference Values
CD13/14: No established reference range
CD19: 2.0-21.0%, 17-750 ABS/mm3
CD2: 70.0-92.0%, 581-3,284 ABS/mm3
CD26: No established reference range
CD3: 59.0-92.0%, 490-3,284 ABS/mm3
CD4: 32.0-62.0%, 266-2,213 ABS/mm3
CD56/16: 3.0-25.0%, 25-893 ABS/mm3
CD7:No established reference range
CD8: 11.0-40.0%, 91-1,425 ABS/mm3
Vb1: 1.89-11.70%
Vb11: 0.25-5.11%
Vb12: 1.00-4.76%
Vb13.1: 1.62-8.16%
Vb13.2: 0.80-5.28%
Vb13.6: 0.84-8.80%
Vb14: 1.33-8.03%
Vb16: 0.42-1.90%
Vb17: 2.28-12.61%
Vb18: 0.58-5.23%
Vb2: 4.03-23.48%
Vb20: 0.00-9.73%
Vb21.3: 1.08-5.97%
Vb22: 1.99-9.89%
Vb23: 0.26-4.76%
Vb3: 0.52-15.71%
Vb4: 0.79-3.26%
Vb5.1: 3.19-14.93%
Vb5.2: 0.49-4.98%
Vb5.3: 0.37-2.98%
Vb7.1: 0.64-20.01%
Vb7.2: 0.05-5.45%
Vb8: 2.26-29.47%
Vb9: 1.10-9.30%
Method Description
Flow cytometry immunophenotyping
Test Classification
This test was developed and its performance characteristics determined The Flow Cytometry Laboratory at The Ohio State University Wexner Medical Center. It has not been cleared or approved by the FDA. This laboratory is certified under the Clinical Laboratory Improvement Amendments (CLIA) as qualified to perform high complexity clinical laboratory testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.
Performing Lab
Clinical Lab UH
Day(s) Performed
Monday through Saturday
Report Available
1 to 7 days
Reporting Name
TCRV Beta by Flow Cytometry, Blood
CPT Code Information
88184
88185 x32