Test Code MIC22 Legionella Culture
Clinical Information
Detection and identification of Legionella spp.
Synonym
- LEGCX
Specimen Required
Preferred Container/Tube: eSwab
Acceptable Container/Tube: eSwab
Specimen Source: Wound, lesion, genital
Specimen Minimum Volume: 1 mL
Preferred Container/Tube: Sterile Container
Acceptable Container/Tube: Sterile Container
Specimen Source: Sterile body fluid, tissue, urine, respiratory
Specimen Minimum Volume: 0.5 mL
Testing Algorithm
When this test is ordered, the reflex tests may be performed at an additional charge.
Reflex Test
Reporting Name | Available Separately | Always Reported |
---|---|---|
Gram Stain | No | No |
MALDI-TOF | No | No |
Reference Values
No growth
Interpretation
Identification of Legionella species from respiratory specimens provides a definitive diagnosis of Legionnaires disease.
Method Description
Culture
Test Classification
Identification was performed on the MALDI-TOF mass spectrometer biotyper. This test was developed by The Clinical Microbiology Laboratory at The Ohio State University Wexner Medical Center. It has not been cleared or approved by the FDA. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.
Performing Lab
Clinical Lab University East
Day(s) Performed
Monday through Sunday
Report Available
Preliminary report: 3 days
Final report: 7 days
Reporting Name
Legionella Culture
CPT Code Information
87081
87077 (if appropriate)
LOINC Code Information
6463-4