Test Code BG2 Venous Blood Gas
Synonym
- GASV5
Profile Information
Reporting Name | Available Separately | Always Reported |
---|---|---|
pH, Venous | No | Yes |
pCO2, Venous | No | Yes |
pO2, Venous | No | Yes |
HCO3, Venous | No | Yes |
O2 Saturation, Venous | No | Yes |
Base Excess | No | Yes |
Specimen Required
Preferred Container/Tube: Dry Lithium Heparin Syringe
Acceptable Container/Tube: Dry Lithium Heparin Syringe
Specimen Volume: Full syringe
Specimen Minimum Volume: Full syringe
Specimen Stability Information
Ambient: 30 minutes
Rejected Due To
- Unacceptable container type
- Quantity not sufficient
- Clotted specimens
- Received >30 minutes from collection time
Reference Values
FEMALE | MALE |
---|---|
pH, Venous
pCO2, Venous
HCO3, Venous
O2 Saturation, Venous
Base Excess |
pH, Venous
pCO2, Venous
HCO3, Venous
O2 Saturation, Venous
Base Excess |
Cautions
pH: Contamination of sample with ambient air will falsely increase the pH.
Method Description
pO2: Amperometry
pH, pCO2: Potentiometry
Base excess GEM: HCO3- - 24.8 + 16.2 x (pH - 7.4)
HCO3 GEM: Log (HCO₃ (c)) = pH + log(pCO₂) – 7.608 mmol/L
sO2: Co-oximetry; sO2 = 100 x O2Hb%/(O2Hb% + HHb%)
Performing Lab
Clinical Lab UH
Clinical Lab West Campus
Respiratory Therapy East
Respiratory Therapy UH
Day(s) Performed
Monday through Sunday
Reporting Name
Venous Blood Gas
CPT Code Information
82803
LOINC Code Information
11558-4
11557-6
11556-8
1959-6
2713-6
11555-0