Test Code CMPN CMPN without Glucose
Synonym
- CMPNG
Profile Information
Reporting Name | Available Separately | Always Reported |
---|---|---|
Sodium | Yes | Yes |
Potassium | Yes | Yes |
Chloride | Yes | Yes |
Carbon Dioxide | Yes | Yes |
BUN | Yes | Yes |
Creatinine | Yes | Yes |
Calcium | Yes | Yes |
BUN/Crea Ratio | No | Yes |
Anion Gap | No | Yes |
eGFR | No | Yes |
Albumin | Yes | Yes |
Bilirubin Total | Yes | Yes |
Alkaline Phosphatase | Yes | Yes |
ALT | Yes | Yes |
AST | Yes | Yes |
Total Protein | Yes | Yes |
Specimen Required
Preferred Container/Tube: Mint Green Top
Acceptable Container/Tube: Mint Green Top, Gold SST Top
Specimen Volume: 3 mL
Specimen Minimum Volume: 2 mL
Specimen Stability Information
Refrigerated: 24 hours
Specimen Collection Information
Outpatient shipping: Protect from light
Rejected Due To
- Gross hemolysis
- Gross icterus
- Quantity not sufficient
- Quality not acceptable
Reference Values
FEMALE | MALE |
---|---|
Sodium
Potassium
Chloride
Carbon Dioxide
BUN
Creatinine
Calcium
Anion Gap
eGFR
Albumin
Bilirubin Total
Alkaline Phosphatase
ALT
AST
Total Protein |
Sodium
Potassium
Chloride
Carbon Dioxide
BUN
Creatinine
Calcium
Anion Gap
eGFR
Albumin
Bilirubin Total
Alkaline Phosphatase
ALT
AST
Total Protein |
Cautions
Na/Cl: Falsely low sodium and chloride results may occur in the presence of hyperlipidemia or hyperproteinemia.
K: Falsely elevated serum/plasma potassium measurements may occur with lysis of red or white blood cells or platelets during or after blood collection.
Creatinine: Creatinine results may be falsely decreased in icteric samples. In some cases of monoclonal gammopathies (especially Waldenstrom's macroglobulinemia with very high concentrations of IgM), creatinine results may be unreliable.
Calcium: Calcium results may be affected in patients who received gadolinium containing contrast media within the past 24 hours (especially patients with impaired renal function).
Albumin: Albumin results may be unreliable in samples with high concentration of paraproteins, especially IgM.
Total Bilirubin: Total bilirubin results are falsely decreased in the presence of hemolysis. In some cases of monoclonal gammopathies (especially Waldenstrom's macroglobulinemia with very high concentrations of IgM), total and direct bilirubin results may be unreliable. Total and direct bilirubin results may be falsely low in the presence of high concentrations of N-acetyl-p-benzoquinone imine (metabolite of Acetaminophen).
AST/ALP/ALT: AST (and to a lesser extent ALP and ALT) may be significantly falsely elevated in the presence of hemolysis. Falsely low ALT results may occur in patients treated with sulfasalazine.
Total Protein: Falsely elevated serum/plasma total protein results may occur in grossly hemolyzed specimen.
Method Description
NA K CL
Indirect ion-selective electrode
CO2
Photometric
BUN
Photometric rate
CREA
Kinetic Jaffe
CA
Photometric, arsenazo
ANION GAP
(Na + K) – (Cl + CO2)
eGFR
CKD-EPI 2021 refit using creatinine, age, and sex
ALB
Colorimetric; Bromocresol green.
TBIL
Photometric with 3,5-dichlorophenyldiazonium tetrafluoroborate (DPD), and caffeine and a surfactant as accelerators.
ALP
Photometric rate with p-nitro-phenylphosphate (pNPP) in the presence of 2-amino-2-methyl-1-propanol (AMP) at pH 10.4.
ALT
Photometric rate with alanine to α-oxoglutarate to form pyruvate and glutamate. This assay does not contain pyridoxyl-5-phosphate.
AST
Photometric rate with aspartate and α-oxoglutarate to form pyruvate and glutamate. This assay does not contain pyridoxyl-5-phosphate.
TP
Colorimetric with cupric ions in an alkaline solution.
Performing Lab
Clinical Lab UH
Clinical Lab University East
Clinical Lab James
Clinical Lab Martha Morehouse
Clinical Lab Spielman
Clinical Lab West Campus
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 day
Reporting Name
CMP Without Glucose
CPT Code Information
80051
82040
82247
82310
82565
84075
84155
84460
84450
84520
LOINC Code Information
2951-2
2823-3
2075-0
2028-9
3094-0
2160-0
17861-6
10466-1
62238-1
1751-7
1975-2
6768-6
1742-6
3097-3
1920-8
2885-2