Sign in →

Test Code IMM137 Circulating Immune Complex, C1q Binding

Additional Codes

YC1Q

Reporting Name

CIC, C1q Binding

Performing Laboratory

ARUP Laboratories

Specimen Type

Serum


Specimen Required


Collection Container/Tube: Red top or serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL serum

Collection Instructions:

1. Allow complete clotting of red blood cells (up to 1 hour).

2. Within 30 minutes after clotting is complete, centrifuge and aliquot serum into a plastic vial.

3. Freeze immediately.

4. Ship frozen.

Note: Critical frozen. Separate specimens must be submitted when multiple tests are ordered.


Specimen Minimum Volume

Serum: 0.3 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen 14 days

Reference Values

Less than or equal to 3.9 ug Eq/mL

Day(s) Performed

Saturday, Monday, and Thursday

CPT Code Information

86332

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FCQBA CIC, C1q Binding 27831-7

 

Result ID Test Result Name Result LOINC Value
Z2636 CIC, C1q Binding 27831-7

Report Available

4 to 15 days

Reject Due To

Gross hemolysis: Reject
Thawing: Cold reject; Warm reject
Non-frozen specimen Reject

Method Name

Semi-Quantitative Enzyme-Linked Immunosorbent Assay

Interpretation

Less than or equal to 3.9 ug Eq/mL is considered negative for circulating complement binding immune complexes.

 

Circulating immune complexes may be found without any evident pathology and positive results do not necessarily implicate the immune complex in a disease process.

Useful For

Detecting circulating immune complexes