Test Code IMML35 ENA Battery (SSA, SSB, SM, RNP)
Synonym
- ENAB
Profile Information
Reporting Name | Available Separately | Always Reported |
---|---|---|
RNP Antibody | Yes | Yes |
Smith Antibody | Yes | Yes |
SSA Antibody | Yes | Yes |
SSB Antibody | Yes | Yes |
Specimen Required
Preferred Container/Tube: Gold SST Top
Acceptable Container/Tube: Gold SST Top
Specimen Volume: 3 mL
Specimen Minimum Volume: 1 mL
Specimen Stability Information
Refrigerated: 7 days
Rejection Due To
- Gross hemolysis
- Microbially contaminated specimens
- Heat inactivated serum specimens
Interpretation
RNP: Negative
SMT: Negative
SSAT: Negative
SSBT: Negative
Method Description
Multiplex flow immunoassay
Performing Lab
Clinical Lab UH
Day(s) Performed
Monday through Friday (excludes OSU holidays)
Report Available
4 to 6 days
Reporting Name
ENA Battery (SSA, SSB, SM, RNP)
CPT Code Information
86235 x4
LOINC Code Information
5301-7
31627-3
53018-8
8094-5