Test Code LAB108 PTH Intact

Clinical Information

Parathyroid hormone (PTH) values should be interpreted in conjunction with serum calcium and phosphorus levels, and the overall clinical presentation and history of the patient. The carboxyl-terminal (PTH-C) fragment 7-84, which accumulates in kidney failure, shows substantial cross-reactivity in this assay. Healthy population reference ranges, therefore, do not apply in kidney failure. Some overlap of intact PTH values does exist for patients with various parathyroid disorders. Measurement of intact PTH is useful in differentiating between hypercalcemia due to hyperparathyroidism and hypercalcemia of malignancy. However, the assay is not intended as, and should not be relied upon as, a diagnostic indicator of malignancy. It is extremely important to ensure that patient samples have been handled and stored correctly. Incorrect handling of samples will result in a loss of intact PTH. For assays employing antibodies, the possibility exists for interference by human anti-animal antibodies (i.e., heterophile antibodies) in the patient sample. Patients who have been regularly exposed to animals or have received immunotherapy or diagnostic procedures utilizing immunoglobulins or immunoglobulin fragments may produce antibodies, (e.g., HAMA), that interfere with immunoassays. This may falsely elevate or falsely decrease the results.

Synonym

  • IPTH
  • Parathyroid Hormone

Specimen Required

Preferred Container/Tube: Lavender Top
Acceptable Container/Tube: Lavender Top, Gold Top
Specimen Volume: 4 mL
Specimen Minimum Volume: 2 mL

Specimen Stability Information

Ambient
        Serum: 8 hours
        Plasma: 25 hours


Refrigerated
        Serum: 8 hours
        Plasma: 14 days

Specimen Collection Information

Centrifuge serum/plasma samples at ≥1000 x g for 15 minutes. 
Serum: physically separated from cells and freeze as soon as possible with a max limit of 2 hours from time of collection.
Plasma: physically separated from cells as soon as possible after collection with the max limit of 24 hours from the time of collection. Aliquot the plasma and put in refrigerator (2-8C).
Outpatient sites: centrifuge sample as soon as possible after collection with the max limit of 24 hours from the time of collection. Aliquot the plasma and ship the aliquot refrigerated. Do not freeze.

Rejection Due To

  • Improperly labeled specimens
  • Gross hemolysis

Reference Values

14.0-72.0 pg/mL

Method Description

Two-site sandwich immunoassay

Performing Lab

Clinical Lab UH
Clinical Lab University East
Clinical Lab West Campus

Day(s) Performed

Monday through Sunday

Report Available

5 to 7 days

Reporting Name

PTH Intact

CPT Code Information

83970

LOINC Code Information

2731-8