Test Code LAB15 Basic Metabolic Panel
Synonym
- BMP
Profile Information
Reporting Name | Available Separately | Always Reported |
---|---|---|
Sodium | Yes | Yes |
Potassium | Yes | Yes |
Chloride | Yes | Yes |
Carbon Dioxide | Yes | Yes |
Glucose | Yes | Yes |
BUN | Yes | Yes |
Creatinine | Yes | Yes |
Calcium | Yes | Yes |
BUN/Crea Ratio | No | Yes |
Osmolality (Calc) | No | Yes |
Anion Gap | No | Yes |
eGFR | No | Yes |
Specimen Required
Preferred Container/Tube: Mint Green Top
Acceptable Container/Tube: Mint Green Top, Gold SST Top
Specimen Volume: 3 mL
Specimen Minimum Volume: 2 mL
Specimen Stability Information
Refrigerated: 24 hours
Rejected Due To
- Gross hemolysis
- Gross icterus
- Quantity not sufficient
- Quality not acceptable
Reference Values
FEMALE | MALE |
---|---|
Sodium
Potassium
Chloride
Carbon Dioxide
Glucose
BUN
Creatinine
Calcium
Osmolality (Calc)
Anion Gap
eGFR |
Sodium
Potassium
Chloride
Carbon Dioxide
Glucose
BUN
Creatinine
Calcium
Osmolality (Calc)
Anion Gap
eGFR ≥60 mL/min/1.73m2 |
Method Description
NA K CL
Indirect ion-selective electrode
CO2
Photometric
GLUC
Photometric rate with hexokinase
BUN
Photometric rate
CREA
Kinetic Jaffe
CA
Photometric, arsenazo
ANION GAP
(Na + K) – (Cl + CO2)
eGFR
CKD-EPI 2021 refit using creatinine, age, and sex
OSMO CALC
(1.86 (Na +K) + 1.15 (Glucose/18) + (Urea/2.8) + 14 where Na and K are in mmol/L; Glucose and Urea are in mg/dL
Cautions
Na/Cl: Falsely low sodium and chloride results may occur in the presence of hyperlipidemia or hyperproteinemia.
K: Falsely elevated serum/plasma potassium measurements may occur with lysis of red or white blood cells or platelets during or after blood collection.
Creatinine: Creatinine results may be falsely decreased in icteric samples. In some cases of monoclonal gammopathies (especially Waldenstrom's macroglobulinemia with very high concentrations of IgM), creatinine results may be unreliable.
Calcium: Calcium results may be affected in patients who received gadolinium containing contrast media within the past 24 hours (especially patients with impaired renal function).
Glucose: Falsely elevated glucose results may occur in patients taking Eltrombopag. In some cases of monoclonal gammopathies (especially Waldenstrom's macroglobulinemia with very high concentrations of IgM), glucose results may be unreliable.
Performing Lab
Clinical Lab UH
Clinical Lab University East
Clinical Lab James
Clinical Lab Martha Morehouse
Clinical Lab Spielman
Clinical Lab West Campus
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 day
Reporting Name
Basic Metabolic Panel
CPT Code Information
80048
LOINC Code Information
2951-2
2823-3
2075-0
2028-9
2345-7
3094-0
2160-0
17861-6
3097-3
18182-6
10466-1
98979-8