Test Code LAB358 Amylase, Urine Random
Synonym
- UAMYR
Specimen Required
Preferred Container/Tube: Urine Container
Acceptable Container/Tube: Urine Container
Specimen Volume: 3 mL
Specimen Minimum Volume: 1 mL
Specimen Stability Information
Ambient: 2 hours
Rejected Due To
- Unacceptable container type
- Sample received past listed stability
Interpretation
The reference range has not been established for random urine specimens. The test result should be integrated into the clinical context for interpretation.
Method Description
Photometric rate
Test Classification
This test has not been cleared or approved by the FDA. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes. It should not be regarded as investigational or for research. This test was developed and its performance characteristics determined by the Critical Care Laboratory at The Ohio State University Wexner Medical Center.
Performing Lab
Clinical Lab UH
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 day
Reporting Name
Amylase, Urine Random
CPT Code Information
82150
LOINC Code Information
25311-2