Test Code LABGASCV Venous Blood Gas, Umbilical Cord
Synonym
- GASCV
Profile Information
Reporting Name | Available Separately | Always Reported |
---|---|---|
pH, Cord Blood Venous | No | Yes |
pCO2, Cord Blood Venous | No | Yes |
pO2, Cord Blood Venous | No | Yes |
HCO3, Cord Blood Venous | No | Yes |
O2 Saturation, Cord Blood Venous | No | Yes |
Base Excess, Cord Blood Venous | No | Yes |
Specimen Required
Preferred Container/Tube: Dry Lithium Heparin Syringe
Acceptable Container/Tube: Dry Lithium Heparin Syringe
Specimen Volume: Full syringe
Specimen Minimum Volume: 1 mL
Specimen Stability Information
Ambient: 30 minutes
Rejected Due To
- Unacceptable container type
- Quantity not sufficient
- Clotted specimens
- Received >30 minutes from collection time
Reference Values
pH, Cord Blood Venous
7.30-7.40
pCO2, Cord Blood Venous
33-44 mm Hg
pO2, Cord Blood Venous
23-35 mm Hg
HCO3, Cord Blood Venous
16-25 mmol/L
O2 Saturation, Cord Blood Venous
16-83 %
Base Excess, Cord Blood Venous
-2.0-2.0 mmol/L
Method Description
pO2: Amperometry
pH, pCO2: Potentiometry
Base: Calculation of the expression that approximates the amount of acid or base required to titrate one liter of blood back to a normal pH of 7.40
HCO3: Calculation
sO2: Cooximetry
Performing Lab
Clinical Lab UH
Day(s) Performed
Monday through Sunday
Reporting Name
Venous Blood Gas, Umbilical Cord
CPT Code Information
82803
LOINC Code Information
28647-6
28645-0
28649-2
1959-6
2713-6
11555-0