Test Code LABPBIRPD Immune Reconst Panel Flow Cytometry
Synonym
- IRP
- PBIRPD
- PBIRP
Profile Information
Reporting Name | Available Separately | Always Reported |
---|---|---|
Alpha Beta | No | Yes |
CD107a+b | No | Yes |
CD117 | No | Yes |
CD127 | No | Yes |
CD13 | No | Yes |
CD134 | No | Yes |
CD158b | No | Yes |
CD159a | No | Yes |
CD16 | No | Yes |
CD183 | No | Yes |
CD19 | No | Yes |
CD193 | No | Yes |
CD194 | No | Yes |
CD25 | No | Yes |
CD27 | No | Yes |
CD29 | No | Yes |
CD294 | No | Yes |
CD3 | No | Yes |
CD31 | No | Yes |
CD314 | No | Yes |
CD4 | No | Yes |
CD45RA | No | Yes |
CD45RO | No | Yes |
CD49a | No | Yes |
CD56 | No | Yes |
CD56/16 | No | Yes |
CD63 | No | Yes |
CD69 | No | Yes |
CD8 | No | Yes |
CD80 | No | Yes |
CD86 | No | Yes |
Gamma Delta | No | Yes |
HLA DR | No | Yes |
Specimen Required
Specimen Type: Peripheral blood
Container/Tube:
Preferred: Lavender Top
Acceptable: Lavender Top, Sodium Heparin, ACD
Specimen Volume: 5-10 mL
Specimen Minimum Volume: 2 mL
Specimen Stability Information
Ambient: 24 hours
Rejected Due To
- Specimens >24 hours old
- Clotted specimens
Reference Values
% |
---|
CD3+: 59.0-92.0% |
ABS/mm3 |
---|
CD3+: 590-4416 ABS/mm3 CD19+: No established reference range CD5616+/CD3-: No established reference range CD13+/HLA DR-: No established reference range CD13+/HLA DR+: No established reference range CD3+/CD69+: 0-50 ABS/mm3 CD3+/CD134+: 0-95 ABS/mm3 CD3+/HLADR+: 0-139 ABS/mm3 CD3+/CD69+/HLADR+: 0-4 ABS/mm3 CD3+/CD134+/HLADR+: 0-2 ABS/mm3 CD3+/CD69+/*CD134+: 0-2 ABS/mm3 CD3+/CD69+/CD134+/HLADR+: 0-0 ABS/mm3 CD3+/CD80+: 0-5 ABS/mm3 CD3+/CD86+: 0-10 ABS/mm3 CD3+/CD80-: 607-2519 ABS/mm3 CD3+/CD86-: 607-2517 ABS/mm3 CD19+/CD80+: 0-11 ABS/mm3 CD19+/CD86+: 0-14 ABS/mm3 CD19+/CD80-: 121-557 ABS/mm3 CD19+/CD86-: 113-554 ABS/mm3 CD19+/CD80-/CD86-: 114-554 ABS/mm3 CD19+/CD80+/CD86+: No established reference range CD3+/CD80-/CD86-: 603-2502 ABS/mm3 CD3+/CD80+/CD86+: 0-0 ABS/mm3 CD4+/CD45RA+: 58-842 ABS/mm3 CD4+/CD45RO+: 146-1011 ABS/mm3 CD8+/CD45RA+: 187-1078 ABS/mm3 CD8+/CD45RO+: 132-816 ABS/mm3 CD4+/CD45RA+/*CD27-: 327-1549 ABS/mm3 CD4+/*CD27+/CD45RA-/CD45RO-: 0-252 ABS/mm3 CD4+/CD45RA+/*CD27+: No established reference range CD4+/CD45RO+/*CD27-: 0-163 ABS/mm3 CD4+/CD45RO+/*CD27+: 94-901 ABS/mm3 CD8+/CD45RA+/*CD27-: 0-341 ABS/mm3 CD8+/*CD27+/CD45RA-/CD45RO-: 0-1 ABS/mm3 CD8+/CD45RA+/*CD27+: 0-426 ABS/mm3 CD8+/CD45RO+/*CD27-: 0-122 ABS/mm3 CD8+/CD45RO+/CD27+: 0-291 ABS/mm3 CD4+/CD45RA+/*CD29-: 131-666 ABS/mm3 CD4+/*CD29+/CD45RA-/CD45RO-: 0-17 ABS/mm3 CD4+/CD45RA+/*CD29+: 0-145 ABS/mm3 CD4+/CD45RO+/*CD29-: 2-201 ABS/mm3 CD4+/CD45RO+/*CD29+: 83-848 ABS/mm3 CD8+/CD45RA+/*CD29-: 0-331 ABS/mm3 CD8+/*CD29+/CD45RA-/CD45RO-: 0-2 ABS/mm3 CD8+/CD45RA+/*CD29+: 30-408 ABS/mm3 CD8+/CD45RO+/*CD29-: 0-56 ABS/mm3 CD8+/CD45RO+/*CD29+: 0-343 ABS/mm3 CD4+/CD31+: No established reference range CD8+/CD31+: No established reference range CD3+/CD49a+: No established reference range CD4+/CD49a+: No established reference range CD8+/CD49a+: No established reference range CD4+/*CD193+: 0-3 ABS/mm3 CD4+/*CD294+: 0-23 ABS/mm3 CD4+/*CD183+: 84-696 ABS/mm3 CD4+/*CD193+/*CD294+: No established reference range CD4+/*CD193+/*CD183+: No established reference range CD4+/*CD193+/*CD294+/*CD183+: No established reference range CD4+/*CD194+: 0-560 ABS/mm3 CD4+/*CD193+/*CD194+: 0-0 ABS/mm3 CD4+/*CD294+/*CD194+: 0-4 ABS/mm3 CD4+/*CD193+/*CD294+/*CD194+: 64-836 ABS/mm3 CD4+/CD25+: 0-68 ABS/mm3 CD4+/CD127+: 318-1487 ABS/mm3 CD8+/CD25+: 0-1 ABS/mm3 CD8+/CD127+: 55-624 ABS/mm3 CD8+/CD127+/CD25-: 50-616 ABS/mm3 CD8+/CD25+/CD127-: 0-0 ABS/mm3 CD4+/CD25+/CD127-: 0-43 ABS/mm3 CD4+/CD25+/CD127+: 0-30 ABS/mm3 CD3+/AlphaBeta+: 50-2158 ABS/mm3 CD3+/GammaDelta+: 0-135 ABS/mm3 CD3+/CD158b+: 0-89 ABS/mm3 CD3-/CD5616-/CD69+: 0-5 ABS/mm3 CD3+/CD69+/CD158b+: 0-3 ABS/mm3 CD3-/CD5616+/CD158b+: 0-178 ABS/mm3 CD3-/CD5616+/CD69+: 0-24 ABS/mm3 CD3-/CD5616+/CD69+/CD158b+: 0-6 ABS/mm3 CD3+/CD159a+: 0-170 ABS/mm3 CD3+/CD107a+b+: 0-6 ABS/mm3 CD3+/CD159a+/CD107a+b+: No established reference range CD3-/CD5616+/CD107a+b+: 0-0 ABS/mm3 CD3-/CD5616+/CD159a+: 0-0 ABS/mm3 CD3-/CD5616+/CD159a+/CD107a+b+: No established reference range CD3+/CD314+: 80-929 ABS/mm3 CD3-/CD5616-/CD63+: 0-48 ABS/mm3 CD3-/CD5616-/CD314+: 0-6 ABS/mm3 CD3+/CD63+/CD314+: 0-11 ABS/mm3 CD3-/CD5616+/CD314+: 0-356 ABS/mm3 CD3-/CD5616+/CD63+/CD314+: 0-48 ABS/mm3 CD16-/CD56-/CD3-/CD117-: No established reference range CD16+CD56-/CD3-/CD117-: 0-122 ABS/mm3 CD16-/CD56+/CD3-/CD117-: 3-24 ABS/mm3 CD16+/CD56+/CD3-/CD117-: No established reference range CD16-/CD56-/CD3+/CD117-: 570-2430 ABS/mm3 CD16+/CD56-/CD3+/CD117-: No established reference range CD16-/CD56+/CD3+/CD117-: 0-157 ABS/mm3 CD16+/CD56+/CD3+/CD117-: No established reference range CD16+/CD56-/CD3+/CD117+: No established reference range CD16-/CD56+/CD3-/CD117+: 0-3 ABS/mm3 CD16+/CD56+/CD3-/CD117+: No established reference range CD16-/CD56-/CD3+/CD117+: No established reference range CD16-/CD56+/CD3+/CD117+: No established reference range CD16+/CD56+/CD3+/CD117+: No established reference range |
Method Description
Flow cytometry immunophenotyping
Test Classification
This test was developed and its performance characteristics determined The Flow Cytometry Laboratory at The Ohio State University Wexner Medical Center. It has not been cleared or approved by the FDA. This laboratory is certified under the Clinical Laboratory Improvement Amendments (CLIA) as qualified to perform high complexity clinical laboratory testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.
Performing Lab
Clinical Lab UH
Day(s) Performed
Monday through Saturday
Report Available
1 to 7 days
Reporting Name
Immune Reconst Panel Flow Cytometry
CPT Code Information
88184
88185 x33